Coolbe: The information about the product is provided by the seller. Notwithstanding any of this information, the product is not intended for diagnosis, cure, mitigation, treatment or prevention of any disease, is not a drug or a medical device, and should not be used for any medical purposes. Please consult a medical specialist.
-----
189 and 280 Wrist sphygmomanometer:
It has no voice function,
Using the oscillometric blood pressure measurement,Accurately measure the blood pressure
LCD digital display,legible
Intelligent pressure
WHO warning message function
Double mode,each of the 99 set of measurements of memory
No operation in 1 minutes automatic shutdown
An irregular heartbeat measurement.
The clock feature
The overpressure protectionfunction.
The product includes: Blood pressure monitor * 1, instruction manual * 1, packaging bag * 1 (foam bag)
Blood pressure monitor model: RAK-289
TIPS: (without battery, without packing box,without USB)
Measurement methods:
1. Tie the sphygmomanometer to your wrist as shown in the picture, paying attention to the position.
2. In order to measure more accurately, please tie the wrist strap tightly.
3. The edge of the wristband is 1-2cm away from the palm (one finger)
4. Click the switch, keep the wristband at the same level as the heart, and don't move or talk.
The error code represents:
Er 1: Due to rapid air leakage or weak pulse signal (please check the wrist strap, tie it up, and test again)
Er 2: Due to noise (please do not move or speak, first clear the air pressure inside the cuff)
Er 3: Abnormal blood pressure. (Please check the position of the cuff and re measure according to the standard posture)
Er P: Unable to apply pressure or pressure too fast. (Check if the cuffs are too tight or loose, check if the trachea is blocked)
HI: Displayed in the low-pressure area, indicating that the pressure exceeds the limit. (Measure again in standard posture, do not move or speak)
Troubleshooting:
1.If there is no display on the screen when the on/off button is pressed, please confirm if the battery is new.
2. If it is impossible to measure or the reading is too high, please re measure with the correct posture
3.If the measured blood pressure is abnormally high or low, please wear a wristband correctly, relax, and then re measure. During the measurement process, please remain quiet and do not speak.
4. If pressing the ON/OFF button,the pressure is not applied but the reading still appears, please turn off the sphygmomanometer first and then turn on the measurement.
5.If the blood pressure measured each time is different and the reading is too high or too low, please relax first. Because in a tense state, the results of each measurement will constantly change, it is recommended to take a deep breath and calm down before taking the measurement.
Finger Pulse Oximeter:
Parameter:SPO2,PR
Certification:CE, FDA,TUV
Display type:LED
Power Requirement:2 x AAA 1.5V alkaline battery(not included)
Screen resolution:128*64
SPo2 measuring range:70%~99%
PR measuring range:30BPM-240BPM
Power consumption:Below 30m